  1.              NUMBER  : A3TH070390U74
  2.             SUBJECT  : Problem with Some Large SCSI Drives 
  3.                DATE  : 7/11/90
  4.          OS VERSION  : All
  5.            REVISION  :
  6.       SHELL VERSION  :
  7.  
  8.             PROBLEM  : A customer has an Adaptec 1542 controller with a CDC 630MB 
  9. drive and CDC 650MB drive, using the Adaptec VADD that was tested and approved 
  10. by Novell.  When the drive gets 5MB or less space free, they get an error 
  11. "Warning: Fatal dir error on volume XXX FAT sector 1".  They have to reboot the 
  12. file server before anyone can login.
  13.  
  14.            SOLUTION  : Some of the large SCSI drives like the CDC drives vary 
  15. in the amount of cylinders and heads that are actually on the drive.  
  16. Therefore, the drive type may not match correctly.  When NetWare gets out to 
  17. the end of the drive it cannot access the sectors that, in actuality, are not 
  18. there even though they were defined in the drive setup by the VADD.  This 
  19. problem occurs most often when the customer mixes and matches controllers with 
  20. drives.  When buying a controller and drive from the same manufacturer these
  21. incompatibilities are usually fixed.
  22.  
  23. There are two solutions to try.  1) Get the correct drive type information from
  24. the drive manufacturer and install it.  2) Backup the drive, re-intialize it,
  25. and define a smaller NetWare partition.  That way, NetWare will not attempt to 
  26. access the drive beyond the maximum limit.
  27.  
  28. YOUR NAME AND DEPT.  : Tim Hofheins - ATS
  29.  
  30. (Check all that apply)
  31.  
  32.   (X)    This information was verified verbally.
  33.  
  34.   (X)    This information was verified by Engineering.